Rules#

This chapter outlines all requirements a Digital Twin must meet to be successfully ingested and used in Grip. It is organized into several subsections, each covering a different part of the specification.

The following conventions are used throughout this page:

  • SHALL / MUST: Indicates a mandatory requirement

  • SHOULD: Indicates a recommended practice

  • MAY: Indicates an optional feature

Minimum specification validation rules#

[C-1] File MUST be named asset.usda#

A Digital Twin MUST have an asset.usda file. This is the entrypoint into the Digital Twin and has to be fixed for consitency and automatic processes to easily pick up the Digital Twin.

  • Error: When no asset.usda file exists in the root of the delivery

  • Success: When the asset.usda exists

[C-2] A defaultPrim MUST be defined#

The asset.usda file must define a defaultPrim that references the prim to be imported.

Example:

#usda 1.0
(
    defaultPrim = "Root"
)

def Xform "Root"
{
}
  • Error: defaultPrim is missing OR defaultPrim is referencing an unknown prim

  • Success: defaultPrim exists AND references an existing prim

[C-3] Up-Axis MUST be defined#

Each Digital Twin MUST have the upAxis defined in the stage. Grip will respect the value when placing the asset in scenes, so the chosen value must align with the placement of your asset in the OpenUSD file. The specification does not mandate a particular up axis.

Example:

#usda 1.0
(
    upAxis = "Y"
)
  • Error: upAxis is missing

  • Success: upAxis exists

External documentation: OpenUSD up-axis documentation / Setting the stage up axis in NVIDIA Omniverse

[C-4] Scene unit MUST be defined and set to ‘mm’#

In the asset.usda file, the stage’s metersPerUnit metadata MUST be defined with the value 0.001, which represents a scale of millimeters. Grip will not scale objects if another value is used for metersPerUnit.

Verify that the geometry has the correct scale by importing the Digital Twin into one of our reference scenes, which include helper geometry for size validation.

Example:

#usda 1.0
(
    metersPerUnit = 0.001
)
  • Error: metersPerUnit is missing OR has a value that doesn’t match 0.001

  • Success: metersPerUnit exists AND has a value of 0.001

External documentation: Units in OpenUSD from NVIDIA

[C-5] defaultPrim is a Xform#

For Grip to place the asset in scenes, the prim referenced by the stage’s defaultPrim attribute MUST be an Xform so that transformations can be applied.

Example:

#usda 1.0
(
    defaultPrim = "Root"
)

def Xform "Root"
{
}
  • Error: The prim referenced by defaultPrim is not an Xform

  • Success: The prim referenced by defaultPrim is an Xform

[C-6] No transformation ops are set on the defaultPrim#

For assets to be positioned correctly in a scene using transformations applied by Grip, the defaultPrim MUST NOT have any transformations of any kind applied to it.

  • Error: The transformOps contains at least one operation

  • Success: The transformOps list is empty (UsdGeomXformable::GetOrderedXformOps() returns empty list)

[C-7] Digital Twin MUST be self-contained#

All asset paths defined in the Digital Twin’s USD structure and shaders MUST be relative to the file that references them. No absolute paths or paths using asset resolver schemas are allowed.

  • Error: At least one asset path is not relative

  • Success: All assets are relative

Variant validation rules#

[V-1] Configurations MUST only contain certain names#

Grip only supports a limited number of variants with specific names.

The following names are supported:

  • default

  • empty

  • inner_out_of_pack

  • open

  • wet

  • wet_closed

Using any other name will result in an error. The check is case-insensitive.

  • Error: At least one variant name is not supported, or the Configurations variant set is missing.

  • Success: All defined variants for the Configurations variant set in the asset.usda file use one of the supported names.

Artwork validation rules#

[A-1] Artwork names MUST only contain certain names#

At the moment, Grip supports only a limited number of artworks with specific names.

The following names are supported:

  • default

  • clean

  • optimized

  • campaign

  • default_angled

  • clean_angled

  • optimized_angled

Using any other names in the metadata.json will result in an error. The check is case-insensitive.

  • Error: At least one artwork name is not supported.